Dimmable and Standard Electronic Ballasts for UV and Tanning

• 30% Less Energy Use Than Traditional Magnetic Ballasts
• Constant UV Output Eliminates Buck/Boost Transformer
• Draws 25% Less Current Than Magnetic Ballasts
• Extended Lamp Life Reduces Maintenance Costs
• Quiet Operation
• Low Radiant Heat Reduces Air Conditioning Costs
• Lighter Weight Than Magnetic Ballasts
• Dimming models feature Instant Start with 0-10V dimming control and linear (smooth) dimming from 100-70%
  • Standard Models
  • Dimmable Models
  • Technical Details
  • Downloadable Files
FEP-120-600-LFEP-210-600-LFEP-230-600-LSHS4-120-CSHGS1 MID 2
200 L
SHGS2 MID 4
100 L
Operating Voltage120VAC210VAC230VAC120VAC208-240VAC +/- 10%208-240VAC +/- 10%
Max. Current2.861.521.500.3031.851.88
Rated Max. Load320W320W320W21W380W380W
Min. Operating Temp.-18ºC (0ºF)-18ºC (0ºF)-18ºC (0ºF)0ºC (32ºF)0ºC (32ºF)0ºC (32ºF)
Max Case Temp70ºC (158ºF)70ºC (158ºF)70ºC (158ºF)75ºC (167ºF)75ºC (167ºF)75ºC (167ºF)
Ballast DimensionsH 1.25", W 3",
L 18.75"
H1.25", W 3",
L 18.75"
H 1.25", W 3",
L 18.75"
H 1", W 1.45", L 3.09"H 1.73", W 3.11", L 12"H 1.73", W 3.11", L 12"

Lamp Operation

Model Number# of LampsLamp Type/Designation
FEP-120-600-L1 or 2F72 / F79 T12HO

3F24 / F30 / F36 / F48 / F59 / F60 / F64 / F72 / F84 T12HO
4F24 / F30 / F36 / F48 / F59 / F60 / F64 / F72 T12HO
FEP-210-600-L1 or 2 F59 / F72 / F79 T12HO
3 or 4F59 / F72 T12HO
FEP-230-600-L2F72 / F79 T12HO
4F59 / F72T12HO
SHS4-120-C1GPH500T5L
SHGS1 MID 2 200L1 or 2F59 / F60 / F71 / F72 / F73 / F74 / F79 (180W) / F79 (200W) T12VHO
SHGS2 MID 4 100L3 or 4F59 / F71 / F72 / F73 T12HO
SHGS3 MID 6 100 LSHGD1 MID 2 200 LSHGD2 MID 4 100 L
Operating Voltage208-240VAC +/- 10%208-240VAC +/- 10%208-240VAC +/- 10%
Max. Current2.420.991.32
Rated Max. Load600W200W100W
Min. Operating Temp.0ºC (32ºF)0ºC (32ºF)0ºC (32ºF)
Max Case Temp75ºC (167ºF)75ºC (167ºF)75ºC (167ºF)
Ballast DimensionsH 1.77", W 3.11", L 16"H 1.73", W 3.11", L 12"H 1.73", W 3.11", L 12"

Lamp Operation

Model Number# of LampsLamp Type/Designation
SHGS3 MID 6 100 L 5 or 6F59 / F71 / F72 / F73 T12HO
SHGD1 MID 2 200L1 or 2F59T12VHO, F60T12VHO, F71T12VHO, F72T12VHO, F73T12VHO, F74T12VHO, F79T12VHO, F79T12VHO
SHGD2 MID 4 100L3 or 4F59T12HO, F71T12HO, F72T12HO, F73T12HO

Common Specifications

Frequency: 50/60 HZ
Open Circuit Voltage: 600V
Protection Output: Yes
Protection Input: Fuse/MOV
Over Current: Yes
Transient Protection: C62.41 Class A 7 strikes
EMI: FCC PART 18 non-consumer
Regulatory Approvals: UL/cULus
Class P Inherent Thermal Protection: Type 1 Outdoor
Lamp Starting Mode: Instant Start
Sound Rating: A